PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 71, No. 2, February 1991, pp. 90-96

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Watkins, M.
Right arrow Articles by Personius, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Watkins, M.
Right arrow Articles by Personius, W.

Article

Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting

MA Watkins, DL Riddle, RL Lamb, and WJ Personius

Glen Falls Hospital, NY 12801.

The purpose of this study was to examine the intratester and intertester reliability for goniometric measurements of knee flexion and extension passive range of motion (PROM). In addition, parallel-forms reliability for PROM measurements of the knee obtained by use of a goniometer and by visual estimation was examined. The intertester reliability for visual estimates of the PROM of the knee was also examined. Repeated measurements were obtained on 43 patients in a clinical setting. The intraclass correlation coefficients (ICCs) for intratester reliability of measurements obtained with a goniometer were .99 for flexion and .98 for extension. Intertester reliability for measurements obtained with a goniometer was .90 for flexion and .86 for extension. The ICCs for parallel-forms reliability for measurements obtained with a goniometer and by visual estimation ranged from .82 to .94. The intertester reliability for measurements obtained by visual estimation was .83 for flexion and .82 for extension. Results suggest clinicians should use a goniometer to take repeated PROM measurements of a patient's knee to minimize the error associated with these measurements.


This article has been cited by other articles:


Home page
Rheumatology (Oxford)Home page
T. J. Gioe, D. Pomeroy, K. Suthers, and J. A. Singh
Can patients help with long-term total knee arthroplasty surveillance? Comparison of the American Knee Society Score self-report and surgeon assessment
Rheumatology, December 23, 2008; (2008) ken439v1.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
G. D Myer, H. I Brunner, P. G Melson, M. V Paterno, K. R Ford, and T. E Hewett
Specialized Neuromuscular Training to Improve Neuromuscular Function and Biomechanics in a Patient With Quiescent Juvenile Rheumatoid Arthritis
Physical Therapy, August 1, 2005; 85(8): 791 - 802.
[Abstract] [Full Text] [PDF]


Home page
J Hand Surg Eur VolHome page
V. ROSE, C. C. NDUKA, J. A. PEREIRA, M. A. PICKFORD, and H. J. C. R. BELCHER
Visual Estimation of Finger Angles: Do we Need Goniometers?
J Hand Surg Eur Vol., August 1, 2002; 27(4): 382 - 384.
[Abstract] [PDF]


Home page
Am J Sports MedHome page
T. F. Schlegel, M. Boublik, R. J. Hawkins, and J. R. Steadman
Reliability of Heel-Height Measurement for Documenting Knee Extension Deficits
Am. J. Sports Med., July 1, 2002; 30(4): 479 - 482.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
B. Ellis and A. Bruton
A study to compare the reliability of composite finger flexion with goniometry for measurement of range of motion in the hand
Clinical Rehabilitation, May 1, 2002; 16(5): 562 - 570.
[Abstract] [PDF]


Home page
Clin RehabilHome page
H Frost, S E Lamb, and S Robertson
A randomized controlled trial of exercise to improve mobility and function after elective knee arthroplasty. Feasibility, results and methodological difficulties
Clinical Rehabilitation, February 1, 2002; 16(2): 200 - 209.
[Abstract] [PDF]


Home page
ptjournalHome page
M. Lewek, J. Stevens, and L. Snyder-Mackler
The Use of Electrical Stimulation to Increase Quadriceps Femoris Muscle Force in an Elderly Patient Following a Total Knee Arthroplasty
Physical Therapy, September 1, 2001; 81(9): 1565 - 1571.
[Abstract] [Full Text] [PDF]


Home page
Am J EpidemiolHome page
D. E. Feldman, I. Shrier, M. Rossignol, and L. Abenhaim
Risk Factors for the Development of Low Back Pain in Adolescence
Am. J. Epidemiol., July 1, 2001; 154(1): 30 - 36.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
P. Fox, J. Richardson, B. McInnes, D. Tait, and M. Bedard
Effectiveness of a Bed Positioning Program for Treating Older Adults With Knee Contractures Who Are Institutionalized
Physical Therapy, April 1, 2000; 80(4): 363 - 372.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
K L Barker, S E Lamb, M Burns, and A H. Simpson
Repeatability of goniometer measurements of the knee in patients wearing an Ilizarov external fixator: a clinic-based study
Clinical Rehabilitation, February 1, 1999; 13(2): 156 - 163.
[Abstract] [PDF]


Home page
Clin RehabilHome page
B. Ellis, A. Bruton, and J. R Goddard
Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand
Clinical Rehabilitation, November 1, 1997; 11(4): 314 - 320.
[Abstract] [PDF]


Home page
Clin RehabilHome page
M. Callaghan and J. Oldham
An evaluation of exercise regimes for patients with osteoarthritis of the knee: a single-blind randomized controlled trial
Clinical Rehabilitation, August 1, 1995; 9(3): 213 - 218.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Physical Therapy Association.