PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 73, No. 5, May 1993, pp. 316-319

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grabiner, M.
Right arrow Articles by Feuerbach, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grabiner, M.
Right arrow Articles by Feuerbach, J.

Article

Converting Chattecx Balance System vertical reaction force measurements to center of pressure excursion measurements

MD Grabiner, TM Lundin, and JW Feuerbach

Department of Biomedical Engineering, Cleveland Clinic Foundation, OH 44195.

BACKGROUND AND PURPOSE. The purpose of this study was to determine the precision with which the postural stability data generated by the Chattecx Balance System could be converted to center of pressure displacement measurements. SUBJECTS. Two men and one woman were selected to represent a broad range of body sizes (age = 23-33 years, height = 154-175 cm, weight = 45-80 kg). METHODS. The Balance System load cells were placed on a force plate, and data were collected simultaneously from the Balance System and the force plate while the subjects performed standardized postural tasks. Linear regression analysis was used to characterize the relationship between the estimated center of pressure from the Balance System and the calculated center of pressure from the force plate. RESULTS. Significant linear relationships between the center of pressure estimated from the Balance System and the center of pressure calculated from the force plate were determined (all R2 values = > .90). CONCLUSION AND DISCUSSION. System data can be converted, and the methods recommended for use with the Balance System are described.


This article has been cited by other articles:


Home page
Arch NeurolHome page
R. W. Baloh, K. M. Jacobson, K. Beykirch, and V. Honrubia
Static and Dynamic Posturography in Patients With Vestibular and Cerebellar Lesions
Arch Neurol, May 1, 1998; 55(5): 649 - 654.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Physical Therapy Association.