PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 73, No. 9, September 1993, pp. 626-631

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Robinson, M.
Right arrow Articles by Mac Millan, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Robinson, M.
Right arrow Articles by Mac Millan, M

Article

Intrasubject reliability of spinal range of motion and velocity determined by video motion analysis

ME Robinson, PD O'Connor, FR Shirley, and M Mac Millan

Department of Clinical and Health Psychology, University of Florida, Gainesville 32610.

BACKGROUND AND PURPOSE. The purpose of this study was to investigate the repeatability of spinal range of motion (ROM) and movement velocity measurements of patients with chronic low back pain, using a two-dimensional motion analysis system. This apparatus uses reflective markers placed on anatomical landmarks and video digitization to derive ROM measurements from three segments of the spine and associated velocities through the respective ROMs. SUBJECTS. Forty-two patients with chronic LBP underwent ROM and movement velocity testing. METHODS. Each subject was tested twice without removal of the markers to minimize error contribution from differences in marker placement. RESULTS. Results indicated that both the ROM measures and the velocity measures were highly repeatable. Intraclass correlations for the ROM measures ranged from .77 to .96. Velocity measures were also reliable, with intraclass correlation coefficients ranging from .75 to .97. CONCLUSION AND DISCUSSION. Overall, the results seem to indicate that the video motion analysis system used in this study yields repeatable ROM and velocity measures on a clinical population. In practice, however, the measures may reflect greater errors due to the need of examiners to relocate markers at different testing sessions. These systems also offer distinct advantages over other means of obtaining ROM and velocity measures. The results of this study indicate that these measures may be obtained without undue concern for measurement artifact due to the instrumentation reliability.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Physical Therapy Association.