PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 74, No. 1, January 1994, pp. 40-49

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mengelkoch, L.
Right arrow Articles by Lawler, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mengelkoch, L.
Right arrow Articles by Lawler, J

Article

A review of the principles of pulse oximetry and accuracy of pulse oximeter estimates during exercise

LJ Mengelkoch, D Martin, and J Lawler

Department of Medicine, University of Florida, Gainesville 32611.

This article reviews the principles of pulse oximetry and assesses the accuracy of pulse oximeter measurements obtained during exercise, based on reports of 10 studies that evaluated 24 pulse oximeters. Nine of the studies used cycle exercise, and 1 study utilized treadmill running for mode of activity. Subject populations included patients with cardiovascular or pulmonary disorders, nondisabled individuals, and athletes. Studies were performed under normoxic and hypoxic conditions, and 5 of the 10 studies validated 18 pulse oximeters at arterial oxyhemoglobin saturation (%HbO2) levels of < or = 78%. Sixteen of the 24 pulse oximeters (67%), from 7 of the 10 studies, observed pulse oximeter estimates (%SpO2) during exercise to be accurate, at least when %HbO2 was > or = 85% in nonsmokers. However, the degree of accuracy of the pulse oximeters was variable, even among the same models. Recent studies suggest the current generation of finger-probe-equipped pulse oximeters may be more accurate than ear-probe-equipped models. We recommend that clinicians carefully secure the probe; monitor signal strength; be wary of %SpO2 values of < or = 68% to 78% to avoid undetected severe hypoxemia; and be alert to whether a patient is a smoker, in which case %SpO2 will likely be overestimated. Researchers interested in using pulse oximeter estimates should validate their particular pulse oximeter(s) via arterial blood sampling.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
M. B. Schenker, M. Stoecklin, K. Lee, R. Lupercio, R. J. Zeballos, P. Enright, T. Hennessy, and L. A. Beckett
Pulmonary Function and Exercise-associated Changes with Chronic Low-Level Paraquat Exposure
Am. J. Respir. Crit. Care Med., October 1, 2004; 170(7): 773 - 779.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American Physical Therapy Association.