PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 74, No. 12, December 1994, pp. 1125-1133

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Finucane, S.
Right arrow Articles by Rothstein, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Finucane, S.
Right arrow Articles by Rothstein, J.

Case Report

Evaluation of the gravity-correction feature of a Kin-Com isokinetic dynamometer

SD Finucane, TP Mayhew, and JM Rothstein

Department of Physical Therapy, Medical College of Virginia, Virginia Commonwealth University, Richmond 23298-0224.

BACKGROUND AND PURPOSE. Torques reflecting muscle performance must be corrected for the effects of gravity if error-free ratio-scaled data are to be obtained. Ratio-scaled data are necessary, for example, to report muscle performance characteristics in terms of ratios or percentages or in the form of ratios with another muscle (eg, ratio of hamstring to quadriceps femoris muscle peak torque). The purpose of this study was to determine the error associated with the gravity-correction procedure of the Kin-Com dynamometer when a weight or limb segment is weighed at different lever arm positions. METHODS. A known weight was suspended from the lever arm of the Kin-Com dynamometer. The rotational component of gravitational forces on the weight was measured at 11 different angular positions. We compared the force measurement obtained from the Kin-Com with the predicted rotational component at each angular position. The gravitational forces on a subject's limb segment (leg) were then measured at 12 different angular positions in each of two trunk positions (sitting and supine). We compared the force measurement obtained from the Kin-Com with the predicted rotational component for each position. Forces measured for the two trunk positions with the lever arm horizontal were compared. Forces measured with the knee extended were compared with forces measured with the lever arm horizontal. RESULTS. The dynamometer accurately recorded the rotational component of gravitational forces for the weight suspended from the lever arm. There was a progressively greater discrepancy between measured forces and predicted forces for the leg as the lever arm was moved from horizontal to 50 degrees below the horizontal. The force recorded with the Kin-Com was greater when the subject's knee was in full extension than when the lever arm was horizontal, which placed the subject's knee in a flexed position. A small difference was noted between the measured forces with the lever arm horizontal when the subject was sitting compared with when the subject was positioned supine. CONCLUSION AND DISCUSSION. When weighing a leg with this dynamometer, we recommend that the lever arm be as close to the horizontal position as possible. Positions of proximal joints should be chosen that do not put two joint muscles in stretched positions.


This article has been cited by other articles:


Home page
ptjournalHome page
M.-H. Jan, H.-M. Chai, Y.-F. Lin, J. C.-H. Lin, L.-Y. Tsai, Y.-C. Ou, and D.-H. Lin
Effects of Age and Sex on the Results of an Ankle Plantar-Flexor Manual Muscle Test
Physical Therapy, October 1, 2005; 85(10): 1078 - 1084.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Sports. Med.Home page
A Gupta, B Fernihough, G Bailey, P Bombeck, A Clarke, and D Hopper
An evaluation of differences in hip external rotation strength and range of motion between female dancers and non-dancers
Br. J. Sports Med., December 1, 2004; 38(6): 778 - 783.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. V. Smith, K. H. C. Silver, A. P. Goldberg, and R. F. Macko
"Task-Oriented" Exercise Improves Hamstring Strength and Spastic Reflexes in Chronic Stroke Patients
Stroke, October 1, 1999; 30(10): 2112 - 2118.
[Abstract] [Full Text] [PDF]


Home page
Neurorehabil Neural RepairHome page
G. V. Smith, R. F. Macko, K. H. C. Silver, and A. P. Goldberg
Treadmill Aerobic Exercise Improves Quadriceps Strength in Patients with Chronic Hemiparesis Following Stroke: A Preliminary Report
Neurorehabil Neural Repair, January 1, 1998; 12(3): 111 - 118.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American Physical Therapy Association.