PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 74, No. 2, February 1994, pp. 162-174

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by LaStayo, P.
Right arrow Articles by Wheeler, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LaStayo, P.
Right arrow Articles by Wheeler, D.

Article

Reliability of passive wrist flexion and extension goniometric measurements: a multicenter study

PC LaStayo and DL Wheeler

Department of Physical Therapy, College of Health Related Professions, University of Florida, Gainesville 32610.

BACKGROUND AND PURPOSE. The purpose of this study was twofold: (1) to determine whether passive wrist flexion and extension goniometric measurements using ulnar alignment, radial alignment, and volar/dorsal alignment were similar or dissimilar and (2) to examine which of these three techniques had the greatest intratester and intertester reliability. SUBJECTS. One hundred forty patients (141 wrists) were measured. The testers were 32 therapists from eight different hand/upper-extremity clinical sites around the United States. METHODS. Randomly paired testers measured passive wrist flexion and extension. The intraclass correlation coefficient (ICC) was used as an estimate of agreement for both intratherapist (model 3.1) and intertherapist (model 2.1) reliability. RESULTS. Six of the eight clinics showed significant differences among the various goniometric techniques. Flexion intratherapist mean ICCs for the radial, ulnar, and dorsal alignment techniques were .86, .87, and .92, respectively. Extension intratherapist mean ICCs were .80, .80, and .84 for the three techniques. Intertherapist flexion mean ICCs were .88, .89, and .93 for the radial, ulnar, and volar alignment techniques, respectively. Extension intertherapist mean ICCs were .80, .80, and .84 for the three techniques. The standard error of measurement was also used to quantify reliability, with the volar/dorsal alignment technique consistently producing less error than the ulnar and radial alignment techniques. The generalizability theory statistical model was utilized to identify the sources of error. The patient contributed to variance the most, although inherent error within the study, diagnostic category, therapeutic approach, and goniometric technique also contributed. CONCLUSION AND DISCUSSION. The overall results indicated there were differences among the three goniometric techniques. The volar/dorsal alignment technique is the goniometric technique of choice, as it consistently had the greatest reliability.


This article has been cited by other articles:


Home page
J Hand Surg Eur VolHome page
R. R. BINDRA, J. J. DIAS, C. HERAS-PALAU, P. C. AMADIO, K. C. CHUNG, and F. D. BURKE
Assessing Outcome after Hand Surgery: the Current State
J Hand Surg Eur Vol., August 1, 2003; 28(4): 289 - 294.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
B. Ellis and A. Bruton
A study to compare the reliability of composite finger flexion with goniometry for measurement of range of motion in the hand
Clinical Rehabilitation, May 1, 2002; 16(5): 562 - 570.
[Abstract] [PDF]


Home page
J Hand Surg Eur VolHome page
J. C. MACDERMID, E. FOX, R. S. RICHARDS, and J. H. ROTH
Validity of Pulp-to-Palm Distance as a Measure of Finger Flexion
J Hand Surg Eur Vol., October 1, 2001; 26(5): 432 - 435.
[Abstract] [PDF]


Home page
ptjournalHome page
L. N Russek
Examination and Treatment of a Patient With Hypermobility Syndrome
Physical Therapy, April 1, 2000; 80(4): 386 - 398.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
J. H. Geertzen, P. U Dijkstra, R. E Stewart, J. W Groothoff, H. J. T. Duis, and W. H Eisma
Variation in measurements of range of motion: a study in reflex sympathetic dystrophy patients
Clinical Rehabilitation, March 1, 1998; 12(3): 254 - 264.
[Abstract] [PDF]


Home page
Clin RehabilHome page
B. Ellis, A. Bruton, and J. R Goddard
Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand
Clinical Rehabilitation, November 1, 1997; 11(4): 314 - 320.
[Abstract] [PDF]


Home page
Clin RehabilHome page
A. Pandyan, M. Granat, and D. Stott
Effects of electrical stimulation on flexion contractures in the hemiplegic wrist
Clinical Rehabilitation, May 1, 1997; 11(2): 123 - 130.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American Physical Therapy Association.