PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 75, No. 10, October 1995, pp. 854-860

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maher, C
Right arrow Articles by Adams, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maher, C
Right arrow Articles by Adams, R

Article

Is the clinical concept of spinal stiffness multidimensional?

C Maher and R Adams

School of Physiotherapy, Faculty of Health Sciences, University of Sydney, Lidcombe, New South Wales, Australia.

BACKGROUND AND PURPOSE. This study investigated whether the poor reliability of judgments of posteroanterior (PA) spinal stiffness is due to rater bias or is a consequence of raters each having individual concepts of PA stiffness. SUBJECTS. Three pairs of manipulative physical therapists with a minimum of 5 years of experience took part in the study. METHODS. The raters were required to make stiffness judgments of a series of metal springs, and their performance at this task was compared with that obtained when they rated the PA stiffness of patients with low back pain. A range of reliability indices were calculated and evaluated to establish whether rater bias contributed to poor reliability in either task. The relationship between each rater's estimates of the magnitude of the stimuli and the measured stiffness of the springs was also assessed using the Pearson Product-Moment Correlation Coefficient. RESULTS. The average intraclass correlation coefficient (2, 1) for rating spring stiffness was found to be .60, whereas for human spines it was found to be .19. There was no evidence of rater bias contributing to poor reliability for rating stiffness of human spines. The average correlation between the rater's estimates of the magnitude of the stimuli and the measured stiffness of the stimuli was .80. CONCLUSION AND DISCUSSION. Physical therapists demonstrated much better ability to judge spring stiffness than the PA stiffness of human spines. This difference in performance implies that mechanical stiffness is not equivalent to the clinical concept of PA stiffness. Posteroanterior stiffness may have more than one dimension, and individual interpretation of stiffness as a construct may lead to rater disagreement in the clinic. The reliability of judgments of PA spinal stiffness may be enhanced in the future if its dimensions can be identified, defined, and taken into account during clinical procedures.


This article has been cited by other articles:


Home page
ptjournalHome page
R. Landel, K. Kulig, M. Fredericson, B. Li, and C. M Powers
Author Response
Physical Therapy, April 1, 2008; 88(4): 536 - 537.
[Full Text] [PDF]


Home page
ptjournalHome page
R. Landel, K. Kulig, M. Fredericson, B. Li, and C. M Powers
Intertester Reliability and Validity of Motion Assessments During Lumbar Spine Accessory Motion Testing
Physical Therapy, January 1, 2008; 88(1): 43 - 49.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Physical Therapy Association.