PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 78, No. 11, November 1998, pp. 1166-1174

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Bruin, E.
Right arrow Articles by Stussi, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by de Bruin, E.
Right arrow Articles by Stussi, E

Article

Reliability of phase-velocity measurements of tibial bone

ED de Bruin, RH Rozendal, and E Stussi

Biomechanics Laboratory, Swiss Federal Institute of Technology Zurich. debruin@biomech.mat.ethz.ch

BACKGROUND AND PURPOSE: The Bone Stiffness Measurement Device-Swing is capable of measuring the propagation velocity of flexural waves in human tibial bone, which relates to bending stiffness. If the interrater and intrarater reliability of measurements obtained with the device are established, it can be used with confidence in assessing changes in bone. The purposes of this study were to detect potential sources of measurement error and to establish the interrater and intrarater reliability of measurements taken with the device. SUBJECTS AND METHODS: In the first part of the study, a random-effects design was used to obtain phase-velocity measurements in subjects without known orthopedic or neurological impairments. The second part of the study consisted of possible applications of the device with mixed designs on subjects with spinal cord injuries. By means of generalizability theory, multiple sources of error (eg, occasion, clinician, repetition) were estimated. For the clinical trial, 17 persons with spinal cord injuries not older than 5 weeks were tested. RESULTS: The standard error of measurement (SEM) for intrarater reliability measurements ranged from 7.3 to 9.8 m x s(-1) . The SEMs for interrater reliability measurements ranged from 5.7 to 9.5 m x s(-1). The SEMs for measurements obtained by a single clinician in a clinical population ranged from 11.9 to 39.7 m x s(-1). CONCLUSION AND DISCUSSION: The reproducibility of measurements obtained with the device is suitably high for the device to be used for evaluation in clinical and research settings.


This article has been cited by other articles:


Home page
Clin RehabilHome page
E. D de Bruin, V. Dietz, M. A Dambacher, and E. Stussi
Longitudinal changes in bone in men with spinal cord injury
Clinical Rehabilitation, February 1, 2000; 14(2): 145 - 152.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Physical Therapy Association.