PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 78, No. 9, September 1998, pp. 989-998

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bussmann, H.
Right arrow Articles by Stam, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bussmann, H.
Right arrow Articles by Stam, H.

Research Report

Validity and reliability of measurements obtained with an "activity monitor" in people with and without a transtibial amputation

HB Bussmann, PJ Reuvekamp, PH Veltink, WL Martens, and HJ Stam

Institute of Rehabilitation Medicine, Faculty of Medicine and Health Sciences, Erasmus University Rotterdam, The Netherlands.

BACKGROUND AND PURPOSE: In this study, the validity and reliability of measurements obtained with an "Activity Monitor" (AM) were examined. The instrument is designed to monitor ambulatory activity by use of accelerometer signals, and it detects several activities associated with mobility (standing, sitting, lying, transitions, movement-related activities). SUBJECTS: Four men with a transtibial amputation and 4 men without a transtibial amputation participated. METHODS: The subjects performed normal daily activities, during which accelerations were measured and videotape recording were made (reference method). Validity was assessed by calculating agreement scores between the AM output and the videotape recordings and by comparing the number of transitions and the duration of activities determined by both methods. RESULTS: The overall agreement between the AM output and the videotape recordings was 90%. Other agreement scores, in addition to the determination of the number of transitions and the duration of activities, were generally within a range of error of 0% to 10%. CONCLUSION AND DISCUSSION: The reliability and validity of the AM measurements appeared to be good, which supports its potential use in rehabilitation and physical therapy. [Bussmann HBJ, Reuvekamp PJ, Veltink PH, et al. Validity and reliability of measurements obtained with an "Activity Monitor" in people with and without a transtibial amputation.


This article has been cited by other articles:


Home page
Neurorehabil Neural RepairHome page
D. K. White, R. C. Wagenaar, M. E. Del Olmo, and T. D. Ellis
Test-Retest Reliability of 24 Hours of Activity Monitoring in Individuals With Parkinson's Disease in Home and Community
Neurorehabil Neural Repair, July 1, 2007; 21(4): 327 - 340.
[Abstract] [PDF]


Home page
Br. J. Sports. Med.Home page
P M Grant, C G Ryan, W W Tigbe, and M H Granat
The validation of a novel activity monitor in the measurement of posture and motion during everyday activities
Br. J. Sports Med., December 1, 2006; 40(12): 992 - 997.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
R. J van den Berg-Emons, J. B Bussmann, A. H Balk, and H. J Stam
Factors Associated With the Level of Movement-Related Everyday Activity and Quality of Life in People With Chronic Heart Failure
Physical Therapy, December 1, 2005; 85(12): 1340 - 1348.
[Abstract] [Full Text] [PDF]


Home page
Age AgeingHome page
K. M. Culhane, M. O'Connor, D. Lyons, and G. M. Lyons
Accelerometers in rehabilitation medicine for older adults
Age Ageing, November 1, 2005; 34(6): 556 - 560.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
K M Culhane, G M Lyons, D Hilton, P A Grace, and D Lyons
Long-term mobility monitoring of older adults using accelerometers in a clinical environment
Clinical Rehabilitation, March 1, 2004; 18(3): 335 - 343.
[Abstract] [PDF]


Home page
ptjournalHome page
W. G. Janssen, H. B. Bussmann, and H. J Stam
Determinants of the Sit-to-Stand Movement: A Review
Physical Therapy, September 1, 2002; 82(9): 866 - 879.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
H. van den Berg-Emons, J. Bussmann, A. Balk, D. Keijzer-Oster, and H. Stam
Level of Activities Associated With Mobility During Everyday Life in Patients With Chronic Congestive Heart Failure as Measured With an "Activity Monitor"
Physical Therapy, September 1, 2001; 81(9): 1502 - 1511.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Uswatte, W. H. R. Miltner, B. Foo, M. Varma, S. Moran, and E. Taub
Objective Measurement of Functional Upper-Extremity Movement Using Accelerometer Recordings Transformed With a Threshold Filter
Stroke, March 1, 2000; 31(3): 662 - 667.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Physical Therapy Association.