PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 81, No. 8, August 2001, pp. 1437-1445

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Patterson, R. M
Right arrow Articles by Nassif, M. D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Patterson, R. M
Right arrow Articles by Nassif, M. D

Technical Reports

Material Properties of Thera-Band Tubing

Rita M Patterson, Caroline W Stegink Jansen, Harry A Hogan and Michael D Nassif

RM Patterson, PhD, is Associate Professor and Biomedical Engineer, Department of Orthopaedic Surgery and Rehabilitation, The University of Texas Medical Branch at Galveston, 301 University Blvd, Galveston, TX 77555-0892 (USA) (Rita.Patterson{at}utmb.edu).
CW Stegink Jansen, PT, PhD, is Assistant Professor, Department of Physical Therapy, The University of Texas Medical Branch at Galveston, Galveston, Tex
HA Hogan, PhD, is Associate Professor and Mechanical Engineer, Department of Mechanical Engineering, Texas A&M University, College Station, Tex
MD Nassif is a mechanical engineering student at Texas A&M University

Address all correspondence to Dr Patterson

Background and Purpose. Thera-Band Tubing has been used in rehabilitation to provide resistance for exercise and splinting. However, the forces required to stretch the tubing have not been thoroughly quantified. Therefore, the therapist cannot assess, with certainty, how much force is applied when using a given length and type of Thera-Band Tubing. The purpose of this study was to quantify the material properties of Thera-Band Tubing. Methods. Force versus percentage of strain for all types of Thera-Band Tubing was measured during elongation in a mechanical testing machine. Results. The material is very compliant and displays nonlinear behavior in the initial stretching phase and linear behavior after 50% elongation. Discussion and Conclusion. From the data obtained in this project, plots that can provide the therapist with information about the forces needed for exercises with Thera-Band Tubing were generated. These data should allow therapists to make better choices about which size of tubing to use for each patient.

Key Words: Material properties • Mechanics of elastic materials • Rehabilitation • Strength training




This article has been cited by other articles:


Home page
Am J Sports MedHome page
R. K. Shields, S. Madhavan, E. Gregg, J. Leitch, B. Petersen, S. Salata, and S. Wallerich
Neuromuscular Control of the Knee During a Resisted Single-Limb Squat Exercise
Am. J. Sports Med., October 1, 2005; 33(10): 1520 - 1526.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Sports. Med.Home page
T W Kaminski, B D Buckley, M E Powers, T J Hubbard, C Ortiz, and C G Mattacola
Effect of strength and proprioception training on eversion to inversion strength ratios in subjects with unilateral functional ankle instability * Commentary
Br. J. Sports Med., October 1, 2003; 37(5): 410 - 415.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Physical Therapy Association.