PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 82, No. 10, October 2002, pp. 1000-1008

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Segers, P.
Right arrow Articles by Verdonck, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Segers, P.
Right arrow Articles by Verdonck, P.

Technical Reports

Excessive Pressure in Multichambered Cuffs Used for Sequential Compression Therapy

Patrick Segers, Jean-Paul Belgrado, Andre Leduc, Olivier Leduc and Pascal Verdonck

P Segers, PhD, is Post-doctoral Researcher, Hydraulics Laboratory, Institute Biomedical Technology, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent, Belgium (patrick.segers{at}navier.rug.ac.be). Address all correspondence to Dr Segers
JP Belgrado, PT, is Researcher, Service de Kinésitherapie et de Readaptation, Université Libre de Bruxelles, Avenue FD Roosevelt 50, B-1050 Bruxelles, Belgium
A Leduc, PhD, is Professor, Service de Kinésitherapie et de Readaptation, Université Libre de Bruxelles
O Leduc, PhD, is Post-doctoral Researcher, Service de Kinésitherapie et de Readaptation, Université Libre de Bruxelles
P Verdonck, PhD, is Professor, Hydraulics Laboratory, Institute Biomedical Technology, Ghent University

Background and Purpose. Pneumatic compression devices, used as part of the therapeutic strategy for lymphatic drainage, often have cuffs with multiple chambers that are inflated sequentially. The purpose of this study was to investigate (1) the relationship between cuff chamber pressure (Pchamber) and the pressure on the cuff-skin interface (Pinterface) and (2) the mechanical interaction of cuff chambers and consequences for device control. Subjects and Methods. In this study, we used 3 cylindrical (60-, 80-, and 100-mm-diameter) model limbs and 1 ellipsoidal model of the arm to test a commercially available pressure controller using "target pressures," indicated by the controller, of 30, 60, 80, and 100 mm Hg. We studied the time course of Pchamber and Pinterface during the inflation sequence and the effect of local curvature on Pinterface. Results. Our data indicated that, overall, Pinterface is of the same order of magnitude as Pchamber. There was some effect of model diameter and shape, with the smaller curvatures yielding the highest Pinterface. Cuff chamber interaction led to Pchamber and Pinterface values in the most distal (first inflated) chamber that were up to 80% higher than the target pressure. For the 80-mm cylindrical model, for instance, pressure in this chamber reached 54, 98, 121, and 141 mm Hg, respectively, instead of the 30, 60, 80, and 100 mm Hg indicated by the controller. Discussion and Conclusion. The discrepancy between the target pressure, indicated by the controller, and the pressure measured inside the cuff chambers undermines the therapeutic control and efficacy of the pneumatic compression devices. Because the measured pressures were far beyond the pressure level indicated by the controller, it is recommended that pneumatic compression devices be used at much lower target pressures (<30 mm Hg) than those applied in clinical practice.

Key Words: Breast cancer • Compression therapy • Deep venous thrombosis • Lymphedema • Mastectomy • Therapy




This article has been cited by other articles:


Home page
ptjournalHome page
H. N Mayrovitz
Interface Pressures Produced by Two Different Types of Lymphedema Therapy Devices
Physical Therapy, October 1, 2007; 87(10): 1379 - 1388.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Physical Therapy Association.