JM Brismée, PT, MS, OCS, is Assistant Professor, School of Allied Health, Texas Tech University Health Sciences Center, 1400 Wallace Blvd, Amarillo, TX 79106 (USA) (brismee{at}cortex.ama.ttuhsc.edu), and Faculty Member, International Academy of Orthopaedic Medicine (IAOM-US), Tucson, Ariz. Address all correspondence to Mr Brismée at the first address
NS Latman, PhD, is Associate Professor, School of Allied Health, Texas Tech University Health Sciences Center
Background and Purpose. Physiological effects of therapeutic ultrasound (US) are dependent on the intensity and duration of application. The purpose of this study was to test US machines used in clinical settings for proper calibration of time and power output. Methods. Measurements of power output and timer accuracy were obtained from 83 US units in clinical use. The machines were tested at 4 intensity settings (0.5, 1.0, 1.5, and 2.0 W/cm2) using a continuous waveform and a 1-MHz frequency. The measured intensities were converted to percentages of error and compared with the ±20% standard. Results. Of the machines tested, 32 (39%) were outside the calibration standard for at least one output setting. Of these machines, 15 (18%) were above the +20% standard, and 17 (21%) were below the 20% standard for at least one output setting. Of the 32 machines outside the standard, 26 (31%) were outside the standard for 2 or more settings, and 3 (4%) produced no output at any of the settings. Of the mechanical timers tested, 7 (28%) were outside of the ±10% standard for timer accuracy at the 5-minute interval, and 6 (24%) were outside of the standard at the 10-minute interval. All digital timers tested were within the standard. Discussion and Conclusion. More than one third of machines tested in this study were outside the standard for power output, and approximately one fourth of the mechanical timers were outside the standard. Therefore, further improvements in the accuracy of US machine calibration are needed.
Key Words: Calibration Physical agent Standards Ultrasound
This article has been cited by other articles:
![]() |
S. J Straub, L. D Johns, and S. M Howard Variability in Effective Radiating Area at 1 MHz Affects Ultrasound Treatment Intensity Physical Therapy, January 1, 2008; 88(1): 50 - 57. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. J Robertson Invited Commentary Physical Therapy, August 1, 2007; 87(8): 995 - 999. [Full Text] [PDF] |
||||
![]() |
S. J Warden, R. K Fuchs, C. K Kessler, K. G Avin, R. E Cardinal, and R. L Stewart Ultrasound Produced by a Conventional Therapeutic Ultrasound Unit Accelerates Fracture Repair Physical Therapy, August 1, 2006; 86(8): 1118 - 1127. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |