PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 83, No. 9, September 2003, pp. 806-815

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schreuders, T. A.
Right arrow Articles by Stam, H. J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schreuders, T. A.
Right arrow Articles by Stam, H. J
Related Collections
Right arrow Injuries and Conditions: Hand
Right arrow Tests and Measurements
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Research Reports

Measurement Error in Grip and Pinch Force Measurements in Patients With Hand Injuries

Ton AR Schreuders, Marij E Roebroeck, Janine Goumans, Johan F van Nieuwenhuijzen, Theo H Stijnen and Henk J Stam

TAR Schreuders, PT, is Physical Therapist, Department of Rehabilitation Medicine, Hand Therapy Unit, Erasmus MC–University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, the Netherlands (a.schreuders{at}erasmusmc.nl).
ME Roebroeck, PhD, is Assistant Professor, Department of Rehabilitation Medicine, Erasmus MC-University Medical Center Rotterdam
J Goumans, MD, is Medical Student, Erasmus MC-University Medical Center Rotterdam
JF van Nieuwenhuijzen, PT, is Research Therapist, Department of Rehabilitation Medicine, Erasmus MC-University Medical Center Rotterdam
TH Stijnen, PhD, is Professor of Biostatistics, Department of Epidemiology and Biostatistics, Erasmus MC-University Medical Center Rotterdam
HJ Stam, MD, PhD, is Professor of Rehabilitation Medicine and Chairman, Department of Rehabilitation Medicine, Erasmus MC-University Medical Center Rotterdam

Address all correspondence to Mr Schreuders

Background and Purpose. There is limited documentation of measurement error of grip and pinch force evaluation methods. The purposes of this study were (1) to determine indexes of measurement error for intraexaminer and interexaminer measurements of grip and pinch force in patients with hand injuries and (2) to investigate whether the measurement error differs between measurements of the injured and noninjured hands and between experienced and inexperienced examiners. Subjects. The subjects were a consecutive sample of 33 patients with hand injuries who were seen in the Department of Rehabilitation Medicine of Erasmus MC–University Medical Center Rotterdam in the Netherlands. Methods. Repeated measurements were taken of grip and pinch force, with a short break of 2 to 3 minutes between sessions. For the grip force in 2 handle positions (distance between handles of 4.6 and 7.2 cm, respectively), tip pinch (with the index finger on top and the thumb below, with the other fingers flexed) and key pinch force (with the thumb on top and the radial side of the index finger below) data were obtained on both hands of the subjects by an experienced examiner and an inexperienced examiner. Intraclass correlation coefficients (ICCs), standard errors of measurement (SEMs), and associated smallest detectable differences (SDDs) were calculated and compared with data from previous studies. Results. The reliability of the measurements was expressed by ICCs between .82 and .97. For grip force measurements (in the second handle position) by the experienced examiner, an SDD of 61 N was found. For tip pinch and key pinch, these values were 12 N and 11 N, respectively. For measurements by the inexperienced examiner, SDDs of 56 N for grip force and 13 N and 18 N for tip pinch and key pinch were found. Discussion and Conclusion. Based on the SEMs and SDDs, in individual patients only relatively large differences in grip and pinch force measurements can be adequately detected between consecutive measurements. Measurement error did not differ between injured and noninjured hands or between experienced and inexperienced examiners. Criteria for judging whether the measurement error does allow application of the measurements in individual patients are discussed.

Key Words: Hand • Hand force • Hand injuries • Measurement error • Reliability of results


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Neurorehabil Neural RepairHome page
H.-M. Chen, C. C. Chen, I-P. Hsueh, S.-L. Huang, and C.-L. Hsieh
Test-Retest Reproducibility and Smallest Real Difference of 5 Hand Function Tests in Patients With Stroke
Neurorehabil Neural Repair, June 1, 2009; 23(5): 435 - 440.
[Abstract] [PDF]


Home page
JBJSHome page
L. M. Buffart, M. E. Roebroeck, W. G.M. Janssen, A. Hoekstra, R. W. Selles, S. E.R. Hovius, and H. J. Stam
Hand Function and Activity Performance of Children with Longitudinal Radial Deficiency
J. Bone Joint Surg. Am., November 1, 2008; 90(11): 2408 - 2415.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
H.M. Molenaar, J. M. Zuidam, R. W. Selles, H. J. Stam, and S. E.R. Hovius
Age-Specific Reliability of Two Grip-Strength Dynamometers When Used by Children
J. Bone Joint Surg. Am., May 1, 2008; 90(5): 1053 - 1059.
[Abstract] [Full Text] [PDF]


Home page
NeurologyHome page
R. W. Selles, B.T.J. van Ginneken, T. A.R. Schreuders, W. G.M. Janssen, and H. J. Stam
Dynamometry of intrinsic hand muscles in patients with Charcot-Marie-Tooth disease
Neurology, December 12, 2006; 67(11): 2022 - 2027.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
E. Svensson and C. Hager-Ross
Hand function in Charcot Marie Tooth: test retest reliability of some measurements
Clinical Rehabilitation, October 1, 2006; 20(10): 896 - 908.
[Abstract] [PDF]


Home page
Clin RehabilHome page
B van Baalen, E Odding, M P. van Woensel, M A van Kessel, M E Roebroeck, and H J Stam
Reliability and sensitivity to change of measurement instruments used in a traumatic brain injury population
Clinical Rehabilitation, August 1, 2006; 20(8): 686 - 700.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Physical Therapy Association.