|
|
||||||||
Research Reports |
S Morris, MAppSc, BAppSc(PT), Grad Dip (PT), is a private practitioner in Melbourne, Victoria, Australia
ME Morris, PhD, MAppSc, BAppSc(PT), Grad Dip (Gerontology), is Professor and Head, School of Physiotherapy, La Trobe University, Victoria 3086, Australia (m.morris{at}latrobe.edu.au). Address all correspondence to Dr Morris
R Iansek, PhD, FRACP, is Neurologist and Director, Movement Disorders Program, Kingston Centre, Cheltenham, Victoria 3192, Australia
Susan Morris and Meg Morris provided concept/research design, writing, and data analysis. Susan Morris provided data collection and project management, and Meg Morris provided fund procurement. Robert Iansek provided subjects and administrative support
Submitted November 10, 1999;
Accepted August 30, 2000
| Abstract |
|---|
Key Words: Gait Levodopa Locomotion Mobility Parkinson disease Physical therapy Turning
| Introduction |
|---|
|
|
|---|
The "Get-up and Go" Test10 was designed to measure mobility in elderly people and has been advocated as a useful tool for quantifying locomotor performance in people with PD.11 This test requires people to stand up from a chair, walk 3 m, turn around, walk back to the chair, and sit down again. The subject is videotaped, and then mobility is rated on a 5-point scale, ranging from "normal" to "severely abnormal." Mathias et al10 found only moderately good correlations (r=.21.75) between "Get-up and Go" Test scores and laboratory measurements of gait and balance in elderly people (mean age=73.8 years, range=5294 years), although there were differences in ratings between medical practitioners and physical therapists. One of the difficulties with this test is that guidelines for rating the severity of abnormality are not provided by the test developers, other than to say that "severely abnormal means that the subject appears at risk of falling during the test performance."10(p387) The lack of guidelines may account for why there is wide interrater variability in scores and difficulty grading the performance for intermediate zones of the scale.
To increase the reliability of the measurements while ensuring that the test continued to be quick and easy to administer, Podsiadlo and Richardson12 modified the "Get-up and Go" Test to incorporate a timed component. When validating the Timed "Up & Go" Test (TUG), a selection of elderly patients (aged 6090 years) with stroke, PD, arthritis, cerebellar disorders, and general deconditioning followed the same procedure. The task, however, was timed using a stopwatch. Excellent agreement in timed scores was found between raters (intraclass correlation coefficient [ICC]=.99) as well as for the same rater during consecutive clinic visits (ICC=.99). Moreover, the TUG times correlated moderately well with gait speed (r=.55), scores on the Berg Balance Scale (r=.72), and the Barthel Activities of Daily Living Index (r=.51). Although Podsiadlo and Richardson included data obtained for 10 patients with PD in their analysis, the PD data were not presented separately, and the retest reliability and interrater reliability of the TUG scores for patients with idiopathic PD were not documented.
Although Martinez-Martin et al13 showed that TUG scores in a sample of 50 subjects with PD ranged from 5 to 31, with a mean of 14.6 (SD 6.9), they did not evaluate the reliability and validity of the measurements for this patient population. Berg et al14 found good correlations between the TUG and the Berg Balance Scale (r=.76) and Tinetti Balance Scale (r=.74), yet they confined their analyses to older people without PD. Other researchers1420 have used the TUG to measure mobility in elderly people (aged 60-99 years). Although observations suggest that the TUG may be a useful test that is quick and easy to administer, a systematic and controlled trial examining the validity of inferences from the measurements for people with PD has not yet been conducted.
The purposes of our investigation were: (1) to quantify the reliability of measurements obtained with the TUG and (2) to examine whether the measure could be used to detect differences in motor performance across the PD medication cycle. We measured retest reliability of measurements obtained with the TUG over 5 trials in subjects with PD 12 hours after withdrawal of levodopa and then 1 hour after the first dose was given. Reliability over 5 trials also was examined for age- and sex-matched comparison subjects. Interrater reliability of TUG scores was examined for experienced and inexperienced raters. In addition, to assess the discriminative ability of the measure, we examined whether the TUG scores could be used to differentiate between the performance of subjects with PD 12 hours after withdrawal of medication ("off" phase of the medication cycle) and their performance 1 hour after the next dose of levodopa was administered ("on" phase of the medication cycle). The ability to use the measure to detect differences in performance between subjects with PD and comparison subjects also was examined.
| Method |
|---|
|
|
|---|
To be included in the study, subjects had to be able to walk at least 10 m unassisted and without orthoses. We chose this distance because the TUG involves a walk of 6 m. Subjects also had to be willing and able to give informed consent according to the Declaration of Helsinki (1964). Subjects were excluded if they had visual impairment or musculoskeletal, neurological, or cardiovascular disorders that affected locomotion. Subjects with diabetes also were excluded because there was a fasting period from 8:00 PM the day before testing was completed until approximately 10:00 AM the next day. Fasting was necessary because food digestion can have a variable effect on the absorption of levodopa. Subjects who scored less than 29 on the Short Test of Mental Status24 also were excluded because this score predicts dementia in 95% of cases.24 In order to keep within-group variability to a minimum, subjects with severe dystonia or dyskinesia (
7 on the dyskinesia subsection) as judged by use of the United Parkinson's Disease Rating Scale (UPDRS)25 also were excluded from the study.26 The characteristics of the subjects with PD and the comparison subjects are summarized in Tables 1 and 2.
|
|
=165.3, SD=10.2). The comparison subjects were age matched (±2 years) and height matched (±10 cm). In the sample, the mean age was 68.8 years (SD=10.4) for the subjects with PD and 69.9 years (SD=11.1) for the comparison subjects. The mean duration of PD was 9.6 years (SD=6.4, range=126). The height of the comparison subjects ranged from 152 to 178 cm (
=165.7, SD=6.85). The mean Modified Webster Scale27 score at the end of the dose was 14.2 (SD=4.4, range=923). The mean Modified Webster Scale scores at peak dose was 10.2 (SD=4.9, range=317). The Modified Webster Scale27 is a test based on the original Webster Scale developed for PD. In addition to the 10 items contained in the original scale (bradykinesia, rigidity, posture, gait, arm swing while walking, tremor, facies, seborrhea, speech, self-care), 2 items have been added. These items are balance and rising from a chair.27 All items are rated on a 4-point scale (03), giving a possible score of 36. Increasingly higher scores indicate increasing degree of disability. Measurements obtained with the scale have been demonstrated to have good reliability and criterion-related validity by several studies.5,26
Apparatus
Administration of the TUG requires subjects to stand up from a chair, walk 3 m, turn around, walk back to the chair, and sit down.12 The starting position was standardized so that the subjects commenced the test with their feet flat on the floor and their arms resting on the armrests. Two physical therapists with more than 7 years of experience in treating patients with neurological problems timed the performance for each trial using stopwatches. Raters were not advised prior to testing whether the subjects had PD or not. Timing commenced on the word "start" (spoken by SM) and ceased once the subject had stopped moving, after sitting down again in the armchair. This procedure differed from that of Podsiadlo and Richardson,12 who commenced timing on the word "go." We believe that the use of the word "go" could act as an external auditory cue in people with PD,1 which could introduce error that would affect reliability.
Handheld stopwatches (Micronta Sports Timer*) were used by the 2 raters. The error that has been attributed to timing using a stopwatch for measurements of gait speed is 1.1%.28 A firm chair with arms (seat height=50 cm, seat depth=47 cm, seat width=50 cm, armrest height=65 cm) was placed at the start of a 3-m walkway indicated by a length of electrician tape attached to a linoleum floor. Videotaping equipment was arranged on the right-hand side, 4.2 m from the marked walkway (Figure). A wide-angled lens (60° arc) was used so that the test could be videotaped without moving the videocamera. Subjects walked in their regular footwear. Shoes were not removed for testing because subjects in this age group infrequently walk without footwear.
|
For the TUG, each subject was instructed to "stand up and walk at a comfortable speed (preferred speed) to the end of the tape, turn around, walk back to the chair, and sit down." Subjects were permitted one practice trial to familiarize them with the procedure before testing commenced. All trials were videotaped.
To investigate interrater reliability of the TUG scores, we examined the agreement between scores for 3 experienced raters and 3 inexperienced raters. The experienced raters were senior physical therapy clinicians (minimum experience=10 years), and the inexperienced raters were newly registered nurses. Each rater viewed the sequence of performances for the 12 subjects with PD and the 12 comparison subjects. The order of the videotape sequence was randomized in order to reduce the likelihood that raters would anticipate a particular score for a given individual. Raters viewed the videotape independently at least 1 week after testing. The raters were instructed to time each trial using a stopwatch. They were instructed to commence timing with the first forward movement of the head and trunk (due to low audibility of a small number of the videotapes) and to cease timing when the subject was stationary in the chair after completing the test. Despite this departure from the standard procedure of commencing timing on the word "start," there remained excellent agreement among all raters. Raters were permitted to replay trials if they were unable to record a time on the first viewing. None of the raters reported replaying the videotapes for any of the trials. Each videotape took approximately 1 hour to view.
Strategy for Statistical Analysis
For the subjects with PD, correlations between the mean TUG scores for trials 1 and 2, trials 2 and 3, trials 3 and 4, and trials 4 and 5 for the "off" and "on" phases of the levodopa cycle were examined using the Pearson product moment correlation coefficient (r). Prior literature on gait in people with PD has reported Pearson product moment correlation coefficients to summarize retest reliability10,12; thus, we used this statistic to compare our results with previous findings. The same procedure was used to examine correlations from one trial to the next for the comparison subjects. The consistency of the data across the 5 trials of the TUG for the subjects with PD was then examined using a one-way analysis of variance (ANOVA) and a series of planned comparisons using the t statistic. The Bonferroni correction was used to reduce the chance of a type I error, which could occur when multiple t tests are performed.29 The same procedure was used for the comparison subjects to provide reference data against which to interpret the PD results.
Intraclass correlation coefficients (3,1)30 were used to examine the relationship between the scores recorded by the experienced and inexperienced raters. Intraclass correlation coefficients were calculated using the following formula:
|
|
Analyses of variance were used to assess differences between experienced and inexperienced raters for mean TUG scores in the "off" and "on" phases for PD subjects as well as for the comparison subjects. Each of these analyses was confined to trials 2, 3, and 4 because there were differences in ratings between trials 1 and 2 as well as between trials 4 and 5. We viewed trial 1 as a practice trial, and we thought that the final trial was excessively fast due to practice effects.
In order to investigate aspects of sensitivity of the TUG in discriminating changes in performance, t tests were used to examine the differences between the means for trials 2, 3, and 4 in the "off" and "on" phases. In a similar way, the means for trials 2, 3, and 4 at peak dose for the subjects with PD were compared with the means of trials 2, 3, and 4 for the comparison subjects.
Finally, the mean "off" phase TUG scores were correlated with the Modified Webster Scale scores obtained in the "off" phase, and the mean "on" phase TUG scores were correlated with the Modified Webster Scale scores obtained in the "on" phase. We used SPSS for Windows 6.0 (1992) statistical software
for data analyses.
| Results |
|---|
|
|
|---|
2=0.216). The comparisons we planned showed differences in means between trials 1 and 2 (t[11]=1.9, P=.0415,
equals;.025) and trials 4 and 5 (t[11]=2.13, P=.0285,
=.025). There were no differences between trials 2 and 3 and trials 3 and 4. Removal of the first and last trials enhanced the reliability of the measurements because trial 1 was abnormally slow and trial 5 was faster than typical, possibly due to the effects of practice.
|
equals;.025).
Although there was a change in TUG times across the 5 trials in the comparison subjects (F=3.86; df=4,44; P=.009, partial
2=0.26), this was due to differences between trials 1 and 2 (t[11]=1.94, P=.039) (Tab. 3). There was no change in performance across trials 2 through 5 (F=1.69; df=3,33; P=.188). Thus, removal of the first trial enhanced the reliability of the measurements.
Table 4 summarizes correlations between trials for the subjects with PD in the "off" and "on" phases, showing strong, positive linear relationships between consecutive TUG trials. Pearson correlation coefficients (r) ranged from .73 to .99. Similarly, for the comparison subjects, there were strong, positive linear relationships between consecutive TUG trials (r=.90.97).
|
.87, indicating a high degree of agreement for this test across different conditions.
|
To further investigate agreement between experienced and inexperienced raters, the mean scores of the TUG recorded by the experienced raters was correlated with the mean scores recorded by the inexperienced raters in the "off" and "on" phases of the medication cycle. There was a strong, positive linear relationship between the experienced and inexperienced raters for both of these conditions (ICC [3,1]=.998 in both cases). The grand means and standard deviations for all trials of the TUG also showed a high degree of agreement between raters for both "off" and "on" phases (Tab. 6). There were moderately strong, positive linear correlations between the Modified Webster Scale scores and the TUG scores in the "off" phase (r=.62) and in the "on" phase (r=.52).
|
The TUG scores also showed differences between the means of trials 2 through 4 in the subjects with PD at the end of dose (
=17.18) and the means of trials 2 through 4 in the comparison subjects (
=9.66) (t[12.13]=3.78, P=.003). In addition, the TUG was able to discriminate between the means of trials 2 though 4 in the subjects with PD in the "on" phase and the means of trials 2 through 4 in the comparison subjects (t[14.92]=3.79, P=.002).
| Discussion |
|---|
|
|
|---|
The finding that TUG times were most consistent at peak dose of the levodopa cycle supports our previous findings on the repeatability of the temporal and spatial measures of gait in subjects with PD.26 Using footswitch stride analysis to measure a series of 10-m samples of walking, we showed that people with mild to moderately severe PD had highly consistent short-stepped, slow gait patterns when they were tested 1 to 3 hours after their morning dose of levodopa. However, when they were tested 30 minutes prior to the next dose, we found considerable variability and poor correlations between repeat measures of performance. Thus, 2 patterns of mobility are evident in people with PD. One pattern is consistent and repeatable and occurs at peak dose in the medication cycle, and the other pattern is variable and inconsistent and corresponds to the end-of-dose phase of the medication cycle.1,26
When performing neurological assessments for patients with PD, we believe it is important for the physical therapist to sample performance in both the "off" and "on" phases, so that the full spectrum of mobility disorders can be documented. Physical therapy interventions may be more effective if they are tailored to changing mobility status.1 For example, when a person is in the "off" phase, he or she can be instructed to use one set of movement strategies to enhance motor performance. We believe this instruction could include the use of external cues, mental rehearsal, visualization, and deliberately focusing attention on the key components of the movement to be performed. When a person is in the "on" phase, he or she may require fewer or different strategies. According to Morris,1 some patients do not require any physical therapy in that locus of the medication cycle. Optimal physical therapy ensures that neurological assessments and treatments are closely linked, so that changes in rehabilitation and medication can be closely charted using clinical measures that have demonstrated reliability and validity.3 The TUG appears ideally suited to this task because it has strong interrater and retest reliability and is able to clearly differentiate different phases of the levodopa cycle.
To enhance the retest reliability of measurements in this study, 5 TUG trials were performed and the means of trials 2 through 4 were used for analysis. In both the subjects with PD and the comparison subjects, the times on the first trial were generally increased in relation to the mean. The high retest reliability of TUG times we found is comparable to the results of other studies. For example, Podsiadlo and Richardson12 reported retest reliability to be very high (ICC=.99) although they did not document when testing occurred in relation to the medication cycle. Similarly, Thompson and Medley18 found retest reliability (r) for the TUG in elderly people without health problems to range between .81 and .99.
The interrater reliability of the measurements was excellent for both experienced and inexperienced raters, with ICCs (3,1) ranging from .87 to .99. Again, this finding is in agreement with the findings of Podsiadlo and Richardson,12 who noted that reliability (ICC) in a mixed group of raters was .99 for the TUG.
We demonstrated that the TUG scores could be used to clearly differentiate between the performance of subjects with PD and that of comparison subjects, even when the subjects with PD were in the "on" phase of the medication cycle. When in the "on" phase, subjects with PD were still considerably slower than their age-matched counterparts. The TUG scores could also be used to detect differences between the scores obtained from the subjects when they were medicated and the scores obtained when they were not medicated. In the nonmedicated state, performance was slower. In the only other study that investigated mobility across the medication cycle,31 a variation of the "Get-up and Go" Test did not reflect the treatment effects of levodopa. However, the test protocol used by Bowes et al31 relied on manual calculation of the step length, mean double support time, and speed as recorded by a gait assessment trolley, which was a small measurement cart attached to the patient by fine leads. The encumbrance produced by the leads might have increased measurement error. These gait variables could be used to discriminate between the medicated and nonmedicated states, but their reliability was poor (r=.24.53). Furthermore, Bowes and colleagues recorded at 2, 4, and 6 hours after levodopa medication was given, which falls outside the "on" period used in our investigation (60-90 minutes) and, therefore, makes direct comparison of results difficult.
There are a number of limitations of this study that need to be acknowledged. There was a small sample, due to limited access to patients, which limits the generalizability of findings. We, therefore, consider this a pilot study. Subjects also were recruited from a sample of convenience from Kingston Centre in Australia and may not be representative of all people with PD or elderly people without health problems in general. Future investigations would benefit from random sampling wherever possible. The subjects with PD in this study were classified as having mild to moderate PD according to the Modified Webster Scale. The sample did not include people who were more severely affected by PD, people in the earliest stages of the disease, or people with dystonia or dyskinesia. The presence of these movement disorders would be expected to increase variability of performance, thus reducing the reliability of repeat measurements. Despite these limitations, we believe that our study provides evidence establishing the validity of TUG scores in people with idiopathic PD, warranting replication by clinicians in other countries using larger samples of patients.
| Conclusion |
|---|
|
|
|---|
| Footnotes |
|---|
This experiment was conducted in partial fulfillment of the requirements for Susan Morris' postgraduate diploma at the School of Physiotherapy, La Trobe University.
This study was approved by the ethics committees at La Trobe University and Kingston Centre.
This research was undertaken with the assistance of a grant from the Victorian Branch Research Committee, a professional body within the Australian Physiotherapy Association.
* Tandy Electronics, 91 Kurrajong Ave, Mt Druitt, New South Wales 2770, Australia. ![]()
SPSS Inc, 444 N Michigan Ave, Chicago, IL 60640. ![]()
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
C. Zampieri and R. P Di Fabio Balance and Eye Movement Training to Improve Gait in People With Progressive Supranuclear Palsy: Quasi-Randomized Clinical Trial Physical Therapy, December 1, 2008; 88(12): 1460 - 1473. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Ellis, D. I Katz, D. K White, T J. DePiero, A. D Hohler, and M. Saint-Hilaire Effectiveness of an Inpatient Multidisciplinary Rehabilitation Program for People With Parkinson Disease Physical Therapy, July 1, 2008; 88(7): 812 - 819. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Morris, R. H. Harwood, R. Baker, O. Sahota, S. Armstrong, and T. Masud A comparison of different balance tests in the prediction of falls in older women with vertebral fractures: a cohort study Age Ageing, January 1, 2007; 36(1): 78 - 83. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Zampieri and R. P Di Fabio Progressive Supranuclear Palsy: Disease Profile and Rehabilitation Strategies Physical Therapy, June 1, 2006; 86(6): 870 - 880. [Full Text] [PDF] |
||||
![]() |
E. Nordin, E. Rosendahl, and L. Lundin-Olsson Timed "Up & Go" Test: Reliability in Older People Dependent in Activities of Daily Living-- Focus on Cognitive State Physical Therapy, May 1, 2006; 86(5): 646 - 655. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J Brusse, S. Zimdars, K. R Zalewski, and T. M Steffen Testing Functional Performance in People With Parkinson Disease Physical Therapy, February 1, 2005; 85(2): 134 - 141. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. E. Garber and J. H. Friedman Effects of fatigue on physical activity and function in patients with Parkinson's disease Neurology, April 8, 2003; 60(7): 1119 - 1124. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Suteerawattananon, B. MacNeill, and E. J Protas Supported Treadmill Training for Gait and Balance in a Patient With Progressive Supranuclear Palsy Physical Therapy, May 1, 2002; 82(5): 485 - 495. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |