PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 83, No. 6, June 2003, pp. 544-551

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eriksrud, O.
Right arrow Articles by Bohannon, R. W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eriksrud, O.
Right arrow Articles by Bohannon, R. W
Related Collections
Right arrow Tendinitis
Right arrow Tests and Measurements
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Research Reports

Relationship of Knee Extension Force to Independence in Sit-to-Stand Performance in Patients Receiving Acute Rehabilitation

Ola Eriksrud and Richard W Bohannon

O Eriksrud, PT, MSPT, is Physical Therapist, Wilton Physical Therapy, Wilton, Conn
RW Bohannon, PT, EdD, NCS, FAHA, is Professor, Department of Physical Therapy, School of Allied Health, University of Connecticut, 358 Mansfield Rd, U-2101, Storrs, CT 06250-2101 (USA) (RICHARD.BOHANNON{at}UCONN.EDU), and Senior Scientist, Institute of Outcomes Research and Evaluation, Hartford Hospital, Hartford, Conn. Address all correspondence to Dr Bohannon at the first address


Submitted April 30, 2002; Accepted February 4, 2003


    Abstract
 
Background and Purpose. The ability to rise from a chair is important for independence in everyday life. This study was conducted to determine to what extent knee extension force (KEF) could explain independence in sit-to-stand (STS) performance from a standard chair. Subjects and Methods. This was a descriptive and correlational study of patients receiving acute rehabilitation (N=107). Measurements of KEF of both lower extremities were obtained using manual muscle testing (MMT) and hand-held dynamometers (HHDs). The HHD measurements were normalized based on body weight and age- and sex-specific reference values. Measurements of the ability to stand without using the upper extremities (STS [without hands]) and to stand using the upper extremities (STS [with hands]) were correlated with the force measurements. Results. The correlations (r) of the KEF measurements with STS success ranged from .652 to .708 for STS (without hands) and from .545 to .638 for STS (with hands). Body weight added to the explanation of STS (without hands) (R=.662) and STS (with hands) (R=.584) provided by KEF measured by HHD. The receiver operating characteristic curves showed that HHD (weight normalized) was the most sensitive and specific measure for explaining independence in STS. Discussion and Conclusion. Manual and dynamometric measurements of KEF are related to independence in STS. Measurements of KEF quantified with a dynamometer and normalized against body weight provided the most valid, specific, and sensitive cutoff point for explaining STS independence.

Key Words: Activities of daily living • Dynamometry • Measurement • Muscle • Sit-to-stand


    Introduction
 Top
 Abstract
 Introduction
 Method
 Results
 Discussion
 Conclusion
 References
 
The inability to rise from a sitting position is recognized by the World Health Organization (WHO) as a disabling condition.1 Sit-to-stand (STS) performance correlates with walking speed, independent ambulation, and stair climbing.2,3 Difficulty in rising from a sitting position is a predictor of future disability,4 falls,5 nursing home use,6 increased utilization of hospital services,7 and mortality.8 Sit-to-stand performance is one of the activities used in functional indexes and in test batteries of physical functioning.4,9,10

Completion of the STS maneuver is fundamental to transfers and the initiation of gait. Sit-to-stand performance is reduced in many older individuals, particularly women and those who have various pathologies.4,9,1119 The ability to complete an independent chair rise successfully is highly valued by older individuals.20

Although STS performance has been found to be influenced by lower-extremity range of motion and balance, the physiologic variable shown most consistently to relate to STS performance is lower-extremity muscle force.3,10,1719,2123 Wretenberg and Aborelius23 found that the knee extensors contribute 72% of the concentric force at the hip and the knee joint during STS. Bohannon17 estimated that 330 N is needed in bilateral knee extension force (KEF) to successfully stand up once from a chair, but he did not account for body weight. Ploutz-Snyder et al24 indicated that individuals with a force-to-weight ratio of <3.0 N·m/kg are at substantial risk of reduced function in rising from a chair. Other researchers,21 however, have described KEF as a predictor of STS success only when considered in combination with plantar-flexion and hip extension forces. Furthermore, Tinetti and Ginter22 reported that only 44% of people with chair-rise problems had decreased KEF. They, however, used manual muscle testing (MMT), which we consider a subjective measure of force with low sensitivity above the grade 3/5 level.25

Although KEF has an established relationship to STS performance,3,1719,21,23,24 we believed the measure's relevance might be enhanced by normalization using other variables. Measurements of KEF have been normalized to body weight, but on a limited basis.3,18,21,26 We consider this noteworthy because muscle force is known to correlate with body weight. In our opinion, therefore, KEF output, when measured with a dynamometer, might better reflect a force-generation impairment when normalized against body weight. Reference values for KEF for male (n=106) and female (n=125) subjects in different age groups have been published.26 Therefore, it is possible to normalize force measurements with the variables of age and sex.

The relevance of KEF, we believe, also might be enhanced through the establishment of a cutoff point, a value that divides a distribution of scores into 2 classes or categories. A KEF cutoff point, therefore, could serve to formulate goals in therapy or to justify use of an assistive device.

Requirements for KEF will vary with use of the upper extremities on armrests,19,27 due to chair height,18,28,29 and with the technique used to stand.18 Chair height has been found to be a determinant of a person's rising successfully from a chair.18,2831 The knee flexion moment, and therefore the demand on the knee extensors, will increase with a decrease in chair height.18,28,29 Similarly, the demand on the knee extensors of taller individuals may be greater than for shorter individuals when rising from a standard-height chair. Upper-extremity assistance at the time of standing, when the knee flexion moment is greatest, will decrease the knee flexion moment and thus the KEF requirement of the task.19,27 Some older individuals use a stability-maximizing technique during STS. This technique, in which the center of mass is positioned over the base of support before standing is initiated, requires a greater KEF than a technique that uses momentum.28

The purpose of our study was to determine the role of KEF relative to weight, height, sex, and age in completion of one STS maneuver, whether or not the upper extremities were used for assistance. We also sought to establish sensitive, specific, and valid cutoff points of different KEF measures for predicting independence in rising from a chair.


    Method
 Top
 Abstract
 Introduction
 Method
 Results
 Discussion
 Conclusion
 References
 
Subjects

We conducted a descriptive and correlational study that involved the recording, in a separate database, of information from the medical records of patients who were referred and seen by a physical therapist (RWB) for acute rehabilitation. There were 107 subjects, all of whom were taken from the caseload of the second author. Subjects were included in the study if they were able to follow directions, had no lower-extremity amputations, and had no restrictions on lower-extremity movement or weight bearing ordered by a physician.

The subjects were highly variable in age, size, diagnoses, ambulatory independence, and use of assistive devices. The mean age of the subjects was 62.1 years (SD=16.4, range=24–97). Measurements of weight and height were obtained from their medical records. Their mean weight was 76.7 kg (SD=25.3, range=37.3–198.2), and their mean height was 168.6 cm (SD=11.4, range=147.3–193.0). Fifty-five (51.4%) of the subjects were men, and 52 (48.6%) were women. The subjects were divided into 6 groups based on diagnosis (frequency indicated in parentheses): neuromuscular (n=61), postsurgical (n=7), cardiovascular or pulmonary (n=19), trauma (n=4), cancer (n=7), and other (n=9). For descriptive purposes, ambulatory function was quantified by use of the Functional Independence Measure (FIM). The FIM score was assigned based on the Guide to the Uniform Data Set for Medical Rehabilitation, version 5.0.32 The distribution of subjects with an FIM gait score was as follows: FIM 1 (n=27), FIM 2 (n=22), FIM 3 (n=2), FIM 4 (n=22), FIM 5 (n=21), FIM 6 (n=4), FIM 7 (n=9). The use of ambulatory assistive devices was as follows: no device (n=54), cane (n=8), quad cane (n=2), hemiwalker (n=5), rolling platform walker (n=7), rolling walker (n=26), and standard walker (n=5). Of the 54 subjects who were categorized as using no device, 29 were hand assisted by the tester.

Equipment

The instrumented measurements of the subjects' KEFs were obtained using 2 digital hand-held dynamometers (HHDs) and a standard-height chair. The HHDs (Ametek Cadet Gauge and Ametek Accuforce II)* were calibrated periodically over the course of the study and found to be accurate within 1 N. The chairs used were all armless with a slightly padded seat and 44 to 46 cm high. Such chairs are representative of those typically encountered in everyday life.

Procedure

Maximum isometric KEF was tested by one examiner (RWB) who had over 20 years of experience using HHDs and MMT. The reliability of HHD measurements obtained by the examiner has been established previously for both patients and individuals without known impairments or pathology.33 The reliability of MMT scores also has been established by Wadsworth et al.34 They reported reliability coefficients of .63 to .98 for 11 patients with chronic orthopedic and neuromuscular disorders. Subjects were tested with the HHD while seated upright with the leg vertical and the knee in approximately 90 degrees of flexion to decrease the influence of gravity during testing. They were not allowed to lean back in the chair while being tested. The subjects were asked to take 1 or 2 seconds to come to maximum effort, during which they were to push as hard as possible into the HHD. The counterforce to the KEF was applied by the tester through the HHD, which was perpendicular and just proximal to the malleoli. The subjects were given encouragement and were asked to stop after 4 to 5 seconds. They were given one trial for each lower extremity.35 The peak forces for both lower extremities were recorded in pounds and converted to newtons. Because we were interested in the force that could be used to lift the body's weight against the pull of gravity, we summed the KEF values of the 2 sides and labeled them "HHD (total force)." The HHD (total force) values were normalized based on body weight and labeled "HHD (weight normalized)." This value was further normalized based on age and sex by dividing HHD (weight normalized) by the expected bilateral KEF output of the appropriate age- and sex-referenced described by Bohannon.26 This category was "labeled HHD (norm referenced)" and was limited to subjects (n=106) in the age range to which the reference values applied.26

The MMT of KEF was conducted according to the technique described by Hislop and Montgomery.36 Patients with grades greater than 2 were tested in the chair used for the STS and HHD testing. The numerical grading system (0–5) of the Medical Research Council (MRC) was used.37 Pluses and minuses were designated when required. The scores from one trial of each lower extremity were then converted to a categorical ordinal score (0–12) to facilitate analysis. Consistent with the treatment of HHD values, the ordinal scores assigned to the original MRC grades were as follows: 0=0, 1=1, 1+=2, 2=3, 2=4, 2+=5, 3=6, 3=7, 3+=8, 4=9, 4=10, 4+=11, and 5=12. The ordinal scores of both KEF measures were added together (maximum possible score=24) and labeled "MMT (total)."

Following assumption of a forward position on the seat with their feet flat on the floor, the subjects were given 3 opportunities to attain a standing position without use of their upper extremities (STS [without hands]). Subjects were classified as "able" (1) or "unable" (0). If unable to stand without use of the upper extremities, subjects were given 3 opportunities to stand using the upper extremities (STS [with hands]), that is, by pushing down on the chair or their thighs. They were again classified as "able" (1) or "unable" (0).

Data Analysis

Data analysis was conducted using SYSTAT 10.0 for Windows38 and SPSS 10.0 for Windows.39 Descriptive statistics were calculated first. Zero-order correlations (Pearson r) were calculated among KEF, age, sex, height, weight, and STS performance under 2 conditions (STS [without hands] and STS [with hands]). The correlations were point-biserial correlations because the dependent variable was dichotomous (able versus unable to rise). Hotelling T analyses were used to determine if there was a difference between the KEF measures in their ability to explain STS independence.

Because variables in the study were dichotomous (able versus unable to complete STS), a forward logistic regression analysis was used to determine the effects of multiple independent variables on STS independence. The KEF variables had the highest correlations with STS performance; therefore, these values were introduced first into each prediction model for STS (without hands) and STS (with hands). The subject's age, sex, weight, and height were then added if not already accounted for through normalization. Weight was not entered into the model including HHD (weight normalized) because this KEF measure was already normalized to body weight. Weight, age, and sex were not entered into the model including HHD (norm referenced) because that variable was already normalized based on those measures.

Receiver operating characteristic (ROC) curves40 were generated for the 4 KEF variables (HHD [total force], MMT [total], HHD [weight normalized], and HHD [norm referenced]) against the 2 dependent variables (STS [without hands] and STS [with hands]). These curves were used to determine cutoff points of the different KEF measures with their respective validity, sensitivity, and specificity. The ROC curve has sensitivity values along the y-axis and specificity values along the x-axis. A perfect cutoff point, one with 100% sensitivity and 100% specificity, would be located in the upper left-hand corner of the graph. The point closest to this location was considered the best cutpoint. Sensitivity and specificity values were determined from the x-axis and y-axis of this point, and these values were used in the accompanying data matrix to find the cutoff point value. Validity was described by the proportion of subjects correctly classified as able to succeed at STS, which corresponds to the area under the curve.41


    Results
 Top
 Abstract
 Introduction
 Method
 Results
 Discussion
 Conclusion
 References
 
Descriptive statistics of the 4 KEF measures are presented in Table 1, grouped according to the subjects' ability versus inability to achieve standing (either without use of their hands or with use of their hands). For both categories, the values of the different KEF measures were higher for subjects who were able to complete the STS maneuver than for subjects who were unable to complete the STS maneuver.


View this table:
[in this window]
[in a new window]
Table 1. Mean (Standard Deviation) for Knee Extension Force Measurements Associated With Differences in Stand-up Performancea

 
Zero-order correlation coefficients between the independent variables (KEF measures, age, sex, height, and weight) and the 2 STS variables are presented in Table 2. The coefficients of the different KEF measures correlated with STS performance were all significant (P<.001). They ranged from .652 to .708 for STS (without hands) and from .545 to .638 for STS (with hands). Although varying in magnitude, the coefficients between the KEF measures and STS performance were not found to differ by the Hotelling T analyses. None of the other measures (age, sex, height, or weight) were found to correlate with STS performance. With one exception, with use of multiple logistic regression (Tab. 3), we did not find any measure to add to the explanation of STS performance provided by the KEF measures. That exception was the additional contribution offered by weight to the explanation of STS (without hands) and STS (with hands) by HHD (total force). After accounting for weight, the correlation (R) of HHD (total force) with STS (without hands) was .662 and the correlation of HHD (total force) with STS (with hands) was .584.


View this table:
[in this window]
[in a new window]
Table 2. Correlation of Independent Variables With Sit-to-Stand Performancea

 

View this table:
[in this window]
[in a new window]
Table 3. Multiple Forward Logistic Regression Models for Prediction of Sit-to-Stand Performancea

 
Cutoff points and the proportion of subjects who were correctly classified, as well as sensitivity and specificity, for the 4 KEF measures are presented in Table 4. Of the KEF measures, HHD (weight normalized) could be used to classify the highest proportion of subjects (.928 for STS [without hands] and .899 for STS [with hands]). The HHD (weight normalized) cutoff point for STS (without hands) was determined from the ROC curve (Fig. 1) to be 40.0% of body weight, with a sensitivity of 86.0% and a specificity of 91.2%. With the use of the upper extremities (STS [with hands]), the cutoff point decreased to 31.1% of body weight (Fig. 2), with a sensitivity of 78.1% and a specificity of 82.4%.


View this table:
[in this window]
[in a new window]
Table 4. Receiver Operating Characteristic Curve Analysis of Force Measures Against Sit-to-Stand Independencea

 

Figure 1
View larger version (11K):
[in this window]
[in a new window]
Figure 1. Receiver operating characteristic curve analysis of sensitivity and specificity of hand-held dynamometer (weight normalized) scores for determining the ability of subjects to stand from a standard chair without using the upper extremities. Point on the curve closest to the upper left-hand corner, cutoff point, determined to be 40% of body weight.

 

Figure 2
View larger version (12K):
[in this window]
[in a new window]
Figure 2. Receiver operating characteristic curve analysis of sensitivity and specificity of hand-held dynamometer (weight normalized) scores for determining the ability of subjects to stand from a standard chair using the upper extremities. Point on the curve closest to the upper left-hand corner, cutoff point, determined to be 31.1% of body weight.

 

    Discussion
 Top
 Abstract
 Introduction
 Method
 Results
 Discussion
 Conclusion
 References
 
All of the KEF measures in our study were found to have moderate correlations with STS independence, which is in agreement with previously published data.3,10,1719,2124 Because we found no significant difference between the various KEF measures in their ability to predict STS independence, we believe none can be advocated (as a measure) over another on the basis of correlations. On the basis of ROC curve analysis, however, HHD (weight normalized) appears to have a slight advantage. Forward logistic multiple regression analysis demonstrated that use of body weight added to the correlation of STS (without hands) and STS (with hands) provided by HHD (total force) (Tab. 3). This relationship persisted with STS (with hands) as the dependent variable, we believe because this variable involves the use of the upper extremities, which can decrease the demand that body weight places on the knee extensor muscles during STS performance. This finding shows the importance of taking body weight into consideration, and thus the possible advantage of the HHD (weight normalized) when interpreting performance of the knee extensor muscles. Our findings do not support taking the time to normalize KEF measurements with age- and sex-specific force measurements if prediction of STS performance is desired.

For measures that are designed to predict function, cutoff points, in theory, can be used to identify problems and guide goal setting. There are, however, few functionally relevant cutoff points reported in the literature. Ikezoe et al3 determined that a KEF cutoff point of 45.5% of body weight was needed for independent ambulation. Ploutz-Snyder et al24 reported a torque value of 3.0 N·m/kg of body weight to be important for performance of several activities, including the STS maneuver. However, no cutoff points involving an absolute force measurement normalized to body weight (HHD [weight normalized]) have been published relative to the ability to do the STS maneuver. Bohannon17 estimated an HHD (total force) cutoff point of 330 N and an MMT (total) cutoff point of 22 for independence in the STS maneuver without the use of the upper extremities. In our study, which involved more subjects in a different setting, we found cutoff points of 300 N for HHD (total force) and 20.5 for MMT (total). However, the HHD (weight normalized) cutoff points were consistently found to have the highest sensitivity, specificity, and correct classification proportions for both STS (without hands) and STS (with hands). The usefulness of the cutoff points can be illustrated with an example. If a patient is observed to be unable to stand from a standard armless chair (even when using the upper extremities) and the patient is known to have an HHD (weight normalized) value of 20.0%, we believe it is reasonable to say that the patient has a KEF impairment that might be responsible for the failure to do the STS maneuver because the cutoff point for STS (with hands) is 31.1%. We contend it is also reasonable to set a goal of 31.1% for HHD (weight normalized) if independence in STS is a goal.

There are many variables that were not analyzed in our study that can have an effect on the ability to rise from a sitting position. Balance18,19,42 and technique18,19,28 have been described as influencing STS capabilities. Balance, which we did not quantify, in our view tends to correlate with muscle force, which was measured in our study. Sensation and dizziness are other variables found to correlate with balance,19,42 which we did not quantify in our study. Subjects were not restricted or instructed in a specific chair-rise technique. Other factors such as vision,21,22 available range of motion,21 joint pain,9 and a history of falls13 can affect the ability of patients to rise from a sitting position. We believe the most important factor contributing to the increased success of rising from a sitting position in STS (with hands) as compared with STS (without hands) is upper-extremity muscle force, which we also did not measure. Researchers, we contend, should take this variable into consideration in future research, especially when the upper extremities are used. Our data suggest that upper-extremity muscle force and training of the upper extremities might affect a person's success in rising from a chair.


    Conclusion
 Top
 Abstract
 Introduction
 Method
 Results
 Discussion
 Conclusion
 References
 
Multiple measures of KEF are valuable for explaining STS performance. In our study, HHD measurements normalized to body weight were found to be the best predictor of STS independence. However, the generalization of these measures may be limited by the restriction of measurements to hospitalized adult patients. The KEF required of patients in other settings may vary slightly.


    Footnotes
 
Dr Bohannon provided concept/idea/research design, project management, subjects, facilities/equipment, and institutional liaisons. Both authors provided writing and data collection and analysis.

The study was approved by the Institutional Review Committee of Hartford Hospital.

The Connecticut Chapter of the American Physical Therapy Association supported the study.

* Ametek Test and Calibration Instruments, 8600 Sommerset Dr, Largo, FL 33773. Back


    References
 Top
 Abstract
 Introduction
 Method
 Results
 Discussion
 Conclusion
 References
 

  1. International Classification of Impairments, Disabilities and Handicaps. Geneva, Switzerland: World Health Organization,1980 .
  2. Bohannon RW. Sit-to-stand test for measuring performance of lower extremity muscles. Percept Mot Skills.1995; 80:163–166.[Web of Science][Medline]
  3. Ikezoe T, Asakawa Y, Hazaki H, et al. Muscle strength and muscle endurance required for independent walking and in the elderly. Journal of Physical Therapy Science.1997; 9:19–22.
  4. Guralink JM, Ferrucci L, Simonsick EM, et al. Lower extremity function in persons over the age of 70 years as a prediction of subsequent disability. N Engl J Med.1995; 332:556–561.[Abstract/Free Full Text]
  5. Campbell AJ, Borrie MJ, Spears GF. Risk factors for falls in a community-based prospective study of people 70 years and over. J Gerontol.1989; 44:M112–M117.
  6. Severson MA, Smith GE, Tangalos EG, et al. Patterns and predictors of institutionalization in community-based dementia patients. J Am Geriatr Soc.1994; 42:181–185.[Web of Science][Medline]
  7. Mor V, Wilcox V, Williams R, Hins J. Functional transitions among the elderly: patterns, predictors, and related hospital use. Am J Public Health.1994; 84:1274–1280.[Abstract/Free Full Text]
  8. Manton KG. A longitudinal study of functional change and mortality in the United States. J Gerontol.1988; 43:S153–S161.
  9. Odding E, Valkenburg HA, Algra D, et al. Association of locomotor complaints and disability in the Rotterdam study. Ann Rheum Dis.1995; 54:721–725.[Abstract/Free Full Text]
  10. Rikli RE, Jones J. Development and validation of a functional fitness test for community-residing older adults. Journal of Aging and Physical Activity.1999; 7:129–161.
  11. Csuka M, McCarthy DJ. Simple method for measurement of lower extremity muscle strength. Am J Med.1985; 78:77–81.[Web of Science][Medline]
  12. Guralnik JM, Simonsick EM, Ferrucci L, et al. A short physical performance battery assessing lower extremity function: association with self-reported disability and prediction of mortality and nursing home admission. J Gerontol.1994; 49:M85–M94.
  13. Hart D, Bowling A, Ellis M, Silman A. Locomotor disability an very elderly people: value of a programme for screening and provision of aids of daily living. BMJ.1990; 301(6745):216–220.
  14. Lundgren-Lindquist B, Rundgren JA. Functional capacity of the elderly in Sweden. Int Disabil Stud.1987; 10:6–9.
  15. Sonn U, Frandin K, Grimby G. Instrumental activities of daily living related to impairments and functional limitations in 70-year-olds and changes between 70 and 76 years of age. Scand J Rehabil Med.1995; 27:119–128.[Web of Science][Medline]
  16. Dawson D, Hendershot G, Fulton J. Aging in the Eighties: Functional Limitations of Individuals Age 65 and Over. Hyattsville, Md: National Center for Health Statistics, Public Health Service; 1987; Advance Data From Vital and Health Statistics No. 133 (PHS):87–1250.
  17. Bohannon RW. Alternatives for measuring knee extension strength of the elderly at home. Clin Rehabil.1998; 12:434–440.[Abstract/Free Full Text]
  18. Schenkman M, Hughes MA, Samsa G, Studenski S. The relative importance of strength and balance by functionally impaired older individuals. J Am Geriatr Soc.1996; 44:1441–1446.[Web of Science][Medline]
  19. Alexander NB, Schultz AB, Warwick DN. Rising from a chair: effects of age and functional ability on performance biomechanics. J Gerontol.1991; 46:M91–M98.
  20. Chiou IL, Burnett CN. Values of activities of daily living: a survey of stroke patients and their home therapists. Phys Ther.1985; 65:901–906.[Abstract/Free Full Text]
  21. Brown M, Sinacore DR, Host HH. The relationship of strength to function in the older adult. Gerontol A Biol Sci Med Sci.1995; 50:55–59.
  22. Tinetti ME, Ginter SF. Identifying mobility dysfunctions in elderly patients: standard neuromuscular examination or direct assessment? JAMA.1988; 259:1190–1193.[Abstract/Free Full Text]
  23. Wretenberg P, Aborelius UP. Power and work produced in different leg muscle groups when rising from a chair. Eur J Appl Physiol.1994; 68:413–417.[Web of Science]
  24. Ploutz-Snyder LL, Manini T, Ploutz-Snyder RJ, Wolf DA. Functionally relevant thresholds of quadriceps femoris strength. J Gerontol A Biol Sci Med Sci.2002; 57:B144–B152.[Abstract/Free Full Text]
  25. Van der Ploeg RJO, Oosterhuis HJHG, Reuvekamp J. Measuring muscle strength. J Neurol.1984; 231:200–203.[Web of Science][Medline]
  26. Bohannon RW. Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79. Arch Phys Med Rehabil.1997; 78:26–32.[Web of Science][Medline]
  27. Wretenberg P, Lindberg F, Arborelius UP. Effects of arm rests and different ways of using them on hip and knee load during rising. Clin Biomech.1993; 8:95–101.
  28. Hughes MA, Weiner DK, Schenkman ML, et al. Chair rise strategies in the elderly. Clin Biomech.1994; 9:178–192.
  29. Rodosky MW, Andriacchi TP, Andersson GBJ. The influence of chair height on lower limb mechanics during rising. J Orthop Res.1989; 7:266–271.[Web of Science][Medline]
  30. Finlay OE, Bayles TB, Milling J. Effects of chair rise design, age and cognitive status on mobility. Age Aging.1983; 12:329–335.[Abstract/Free Full Text]
  31. Weiner DK, Long R, Hughes MA, et al. When older adults face the chair-rise challenge: a study of chair height availability and height-modified chair-rise performance in the elderly. J Am Geriatr Soc.1993; 41:6–10.[Web of Science][Medline]
  32. Functional Independence Measure. In: Guide to the Uniform Data Set for Medical Rehabilitation. Version 5.0. Buffalo, NY: Uniform Data System for Medical Rehabilitation,1996 .
  33. Bohannon RW. Intertester reliability of hand-held dynamometry: a concise summary of published research. Percept Mot Skills.1999; 88:899–902.[Web of Science][Medline]
  34. Wadsworth CT, Krishnan R, Sear M, et al. Intrarater reliability of manual muscle testing and hand-held dynametric muscle testing. Phys Ther.1987; 67:1342–1347.[Abstract/Free Full Text]
  35. Bohannon RW, Saunders N. Hand-held dynamometry: a single trial may be adequate for measuring muscle strength in healthy individuals. Physiotherapy Canada.1990; 42:6–9.
  36. Hislop HJ, Montgomery J. Daniels and Worthingham's Muscle Testing: Techniques of Manual Examination. 6th ed. Philadelphia, Pa: WB Saunders Co,1995 :208–210.
  37. Medical Research Council. Aids to the Examination of the Peripheral Nervous System. London, England: HMSO,1976 :1.
  38. SYSTAT 10.0 for Windows. Chicago Ill: SPSS Inc,1999 .
  39. SPSS 10.0 for Windows. Chicago Ill: SPSS Inc,2000 .
  40. Portney LG, Watkins MP. Foundations of Clinical Research: Applications to Practice. 2nd ed. Upper Saddle River, NJ: Prentice Hall,2000 :98–101.
  41. Cantor SB, Sun CC, Tortolero-Luna G, et al. A comparison of c/b ratios from studies using receiver operating characteristic curve analysis. J Clin Epidmiol.1999; 52:885–892.
  42. Lord SR, Murray SM, Chapman K, et al. Sit-to-stand performance depends on sensation, speed, balance, and psychological status in addition to strength in older people. J Gerontol A Biol Sci Med Sci.2002; 57:M539–M543.[Abstract/Free Full Text]

Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Rheumatology (Oxford)Home page
M. O. Harris-Love, J. A. Shrader, D. Koziol, N. Pahlajani, M. Jain, M. Smith, H. L. Cintas, C. L. McGarvey, L. James-Newton, A. Pokrovnichka, et al.
Distribution and severity of weakness among patients with polymyositis, dermatomyositis and juvenile dermatomyositis
Rheumatology, February 1, 2009; 48(2): 134 - 139.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
R. Hasegawa, M. M Islam, Sung Chul Lee, D. Koizumi, M. E Rogers, and N. Takeshima
Threshold of lower body muscular strength necessary to perform ADL independently in community-dwelling older adults
Clinical Rehabilitation, October 1, 2008; 22(10-11): 902 - 910.
[Abstract] [PDF]


Home page
ptjournalHome page
M. Schenkman, J. E Deutsch, and K. M Gill-Body
An Integrated Framework for Decision Making in Neurologic Physical Therapist Practice
Physical Therapy, December 1, 2006; 86(12): 1681 - 1702.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
R. W Bohannon
Manual muscle testing: does it meet the standards of an adequate screening test?
Clinical Rehabilitation, June 1, 2005; 19(6): 662 - 667.
[Abstract] [PDF]


Home page
Clin RehabilHome page
O. Eriksrud and R. W Bohannon
Effectiveness of the Easy-Up Handle in acute rehabilitation
Clinical Rehabilitation, April 1, 2005; 19(4): 381 - 386.
[Abstract] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eriksrud, O.
Right arrow Articles by Bohannon, R. W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eriksrud, O.
Right arrow Articles by Bohannon, R. W
Related Collections
Right arrow Tendinitis
Right arrow Tests and Measurements
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Physical Therapy Association.